服务类别:电缆及连接器屏蔽效能检测
实验室装备有先进的线注入法、三同轴法、三同轴管中管法、吸收钳法等各类屏蔽效能测试系统,能测试各类屏蔽电缆及金属连接器的转移阻抗、耦合和屏蔽衰减及屏蔽效能。
线注入法 三同轴法
吸收钳法 三同轴管中管法
产品标准:
标准号 | 年代 | 名称 | 中文名称 |
ISO 19642-2 | :2019 | Road vehicles — Automotive cables —Part 2: Test methods | 道路车辆 – 汽车电缆 – 第2部分:试验方法 |
IEC 60512-23-3 | :2018 | Connectors for electrical and electronic equipment - Tests and measurements Part 23-3: Screening and filtering tests - Test 23c : Shielding effectiveness of connectors and accessories - Line injection method | 电气和电子设备用连接器-试验和测量 第23-3部分:屏蔽和滤波试验 - 试验23c:连接器和附件的屏蔽效能 - 线注入法 |
ISO 20076 | :2019 | Road vehicles — Test methods and performance requirements for voltage class B connectors | 道路车辆 – B级电压连接器的试验方法和性能要求 |
基础标准
标准号 | 年代 | 名称 | 中文名称 |
IEC62153-4-3 | :2013 | Metallic communication cable test methods – Part 4-3: Electromagnetic compatibility (EMC) – Surface transfer impedance – Triaxial method | 金属通信电缆试验方法第4-3部分:电磁兼容性(EMC)表面转移阻抗 – 三同轴法 |
IEC62153-4-4 | :2015 | Metallic communication cable test methods – Part 4-4: Electromagnetic compatibility (EMC) – Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method | 金属通信电缆试验方法第4-4部分:电磁兼容性(EMC)- 频率到3GHz及以上屏蔽衰减的试验方法,三同轴法 |
IEC62153-4-5 | :2006 | Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) - Coupling or screening attenuation - Absorbing clamp method | 金属通信电缆试验方法第4-5部分:电磁兼容性(EMC)- 耦合和屏蔽衰减 – 吸收钳法 |
IEC62153-4-6 | :2017 | Metallic cables and other passive components test methods – Part 4-6: Electromagnetic compatibility (EMC) – Surface transfer impedance – Line injection method | 金属电缆和其他无源元件试验方法第4-6部分:电磁兼容性(EMC)表面转移阻抗 - 线注入法 |
GB/T 31723.406 IEC 62153-4-6: 2006 | :2015 | Metallic communication cable test methods – Part 4-6: Electromagnetic compatibility (EMC) – Surface transfer impedance – Line injection method | 金属通信电缆试验方法第4-6部分:电磁兼容性(EMC)表面转移阻抗 - 线注入法 |
IEC62153-4-7 | :2018 | Metallic communication cable test methods – Part 4-7: Electromagnetic compatibility (EMC) – Test method for measuring of transfer impedance ZT and screening attenuation as or coupling attenuation aC of connectors and assemblies up to and above 3 GHz – Triaxial tube in tube method | 金属通信电缆试验方法第4-7部分:电磁兼容性(EMC)- 频率到3GHz及以上连接器和组件的传输阻抗ZT和屏蔽衰减或耦合衰减aC的试验方法 - 三同轴管中管法 |
IEC 62153-4-15 | :2015 | Metallic communication cable test methods – Part 4-15: Electromagnetic compatibility (EMC) – Test method for measuring transfer impedance and screening attenuation – or coupling attenuation with triaxial cell | 金属通信电缆试验方法第4-15部分:电磁兼容性(EMC)- 使用三同轴室测量传输阻抗和屏蔽衰减或耦合衰减的试验方法 |
IEC 62153-4-16 | :2016 | Metallic communication cable test methods Part 4-16: Electromagnetic compatibility (EMC) — Extension of the frequency range to higher frequencies for transfer impedance and to lower frequencies for screening attenuation measurements using the triaxial set-up | 金属通信电缆试验方法第4-16部分:电磁兼容性(EMC)- 使用三同轴装置扩展传输阻抗的更高频率和屏蔽衰减的更低频率 |